|
Build Your Online Product Catalogs?
Product Name: |
XRF fluorescence spectrophotometer/gold test equipment
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
X-6800 with SDD detector |
Price Term: |
FOB |
Port of loading: |
TIANJIN |
Minimum Order |
1 |
Unit Price: |
USD27370/PIECE |
|
Technology ***ails : Analysis element :Al 13 to U 92 element Analysis range :10ppm%-99.99% Ability of elements analysis at the same time :45 elements Acceptable sample type: liquid ,powder ,solid Amptek ***ector 1) ***ector type : X-123 SDD 2) ***ecting area : 25mm2 crystal thickness 500¦Ìm 3) ***ector window : berylium window ,suitable for light element ***ecting 4) ***ector distinguishability :127eV Excitation source : X-ray tube with oil/circulating cooling liquid ,MAX 50W ,voltage from 0-49KV ,interval 1kv ,current range 0.01-1mA . High voltage power supplier 1) Voltage and electric current are adjustable MAX 50KV ,1mA 2) Voltage regulation :0.01% ,voltage change rate is 0.01% of full scale from no-load to full load 3) Line regulation :0.01% of full scale for regulated imput voltage range 4) Electric current regulation: 0.01% of full scale from no-load to full load Collimator and Filtering system: 6 kinds of Wave-filter plate together with 5 kinds of collimator size from 1.8mm-5.0mm Signal processor :digital signal processor with 2048 channels ,energy range from 0.5KeV-40KeV. machine temperature controlling : internal air-cooled/oil cooled system and water circulating refrigeration system ,maximum reduce the X-RAY light tube working temperature ,extend the X-ray light tube life ,make sure the machine performance stability and precision. Testing accuracy : 1) High content sample (gold content over 97%) testing error within ¡À0.05 % 2) Gold content over 75% testing error within ¡À0.1% 3) Gold content under 75% testing error within ¡À0.2% 4) Can distinguish 99.9% and 99.99% 5) Iridium element testing in gold and platinum .the iridium testing accuracy up to 0.2%. 6) Gold content in platinum testing .the accuracy up to 0.2% 7) RoHS, helogen Cr,Pb,Cd element testing 8) Coating testing measurement sample size : 330mm*340mm*115mm(hatch close) . (hatch open) unlimited measurement time :5s to 600s adjustable
Software analysis : Qualitative analysis methods: Automatic peak seek |
Company: |
Tianjin Eastlegend Technology Co.,Ltd
|
Contact: |
Ms. Lisa wong |
Address: |
Room 530 ,Kaifa Building ,Huayuan industry park nankai dist . |
Postcode: |
300000 |
Tel: |
86 22 58016896 |
Fax: |
86 22 58016898 |
E-mail: |
|
|
|
|